英文字典中文字典


英文字典中文字典51ZiDian.com



中文字典辞典   英文字典 a   b   c   d   e   f   g   h   i   j   k   l   m   n   o   p   q   r   s   t   u   v   w   x   y   z       







请输入英文单字,中文词皆可:



安装中文字典英文字典查询工具!


中文字典英文字典工具:
选择颜色:
输入中英文单字

































































英文字典中文字典相关资料:


  • What are Thrust Load, Axial Load and Radial Load?
    Re: What are Thrust Load, Axial Load and Radial Load? 01 15 2008 10:29 AM Just think of axial loads as being on the same axis as the shaft of say a centrifugal pump
  • Heim Joint ball joint rod end load ratings? - GlobalSpec
    The axial direction is through the ball bore (assuming the ball is bored) The radial direction is typically in line with the threaded rod or socket The axial load is sometimes called the ball pullout load These joints are much stronger in the radial direction than in the axial -- you can imagine them disassembling in the axial direction
  • Axial, Radial and Transverse (or Transversal) - CR4 Discussion Thread
    - the radial coordinate tells us how far the point is from the centre (the axis) of the shaft whose cross-section is circular; with the axial and radial coordinates, together, tell us that the point is on our piece of paper (axial coordinate) and that it's on a circle of a given radius (the radial coordinate) and whose centre is the shaft's axis;
  • Bearing Housing Tolerance - CR4 Discussion Thread - GlobalSpec
    the load is 150 kg wheel @ 300 RPM which can have vibration due to imbalance and harmonics , radial force against the fixed outer is 4000 N maximum , and intermittent axial load of 3000 N the locknut is intended to stop the whole shaft being pulled out of the bearings axially and ties both bearings rigidly to the shaft to prevent spalling or
  • Pressure Compensated Vs Load Sensing - CR4 Discussion Thread - GlobalSpec
    A Load Sensing Fixed Volume Pump can save energy since it will relieve the excess flow at a 100-150 PSI above the actual pressure the work at any moment requires You can see my explanation of a Load Sensing Fixed Volume Pump in Chapter 8 starting on page 14 in this Ebook on the Hydraulics Pneumatics web site
  • How to calculate axial load of wheels - CR4 Discussion Thread - GlobalSpec
    This axial load will of course always be opposed by the normal force of the axle, that is until the threads get stripped (You did ask for the axial load and not the net axial load ) Now if you go into a turn, you will have to now know the radius of the turn and the angular velocity of the cart through the turn
  • Load Sharing Controller vs PMS - CR4 Discussion Thread
    Load Sharing: Distributing load among generators, as handled by LSC Load Shedding: Reducing load during emergencies to prevent system instability Generator Control: Starting, stopping, and synchronizing generators Data Logging and Monitoring: Tracking system performance and identifying potential problems
  • Axial Load on Horizontal Francis Turbine - CR4 Discussion Thread
    I would be pleased, if some can help me by giving guidance to calculate axial load on Horizontal Francis Turbines Available techincal data, Maximum power put put _1 4 MW Runner Diameter _ 430 mm Shaft Diameter _ 250 mm Best Regards, Asitha from Sri Lanka
  • Induction Motor Starting Current on NO-Load and ON-Load? - GlobalSpec
    The No Load Current will be 35 to 40 % of FULL LOAD CURRENT but Power Factor will be very LOW to the extent of 0 3 to 0 4 For other details pl Refer Standard Text Book of Elec Engg - INDUCTION MOTOR - CIRCLE DIAGRAM, which will clear all your doubts DHAYANANDHAN S
  • Generators: Load Shedding vs. Load Sharing - CR4 Discussion Thread
    So if you had a 1000 kW and 800 kW paralleled, they will both load share equally if you have load sharing governors, but, if you loose the 1000 kW (trips on low oil pressure, for example), the load shed priority panel 'knows' you lost the big unit, and selects 800 kW of remaining loads to still be connected to the bus by shedding all others





中文字典-英文字典  2005-2009